Networking
CAT5e Vs CAT6
by John on Feb.21, 2010, under Networking, TIPS, Troubleshooting
Cat5e and Cat6 Comparision
Category 6 Cabling System and Application
Why do I need all the bandwidth of category 6? As far as I know, there is no application today that requires 200 MHz of bandwidth.
Bandwidth precedes data rates just as highways come before traffic. Doubling the bandwidth is like adding twice the number of lanes on a highway. The trends of the past and the predictions for the future indicate that data rates have been doubling every 18 months. Current applications running at 1 Gb/s are really pushing the limits of category 5e cabling. As streaming media applications such as video and multi-media become commonplace, the demands for faster data rates will increase and spawn new applications that will benefit from the higher bandwidth offered by category 6. This is exactly what happened in the early 90’s when the higher bandwidth of category 5 cabling compared to category 3 caused most LAN applications to choose the better media to allow simpler, cost effective, higher speed LAN applications, such as 100BASE-TX. Note: Bandwidth is defined as the highest frequency up to which positive power sum ACR (Attenuation to Crosstalk Ratio) is greater than zero.
What is the general difference between category 5e and category 6?
The general difference between category 5e and category 6 is in the transmission performance, and extension of the available bandwidth from 100 MHz for category 5e to 200 MHz for category 6. This includes better insertion loss, near end crosstalk (NEXT), return loss, and equal level far end crosstalk (ELFEXT). These improvements provide a higher signal-to-noise ratio, allowing higher reliability for current applications and higher data rates for future applications.
Will category 6 supersede category 5e?
Yes, analyst predictions and independent polls indicate that 80 to 90 percent of all new installations will be cabled with category 6. The fact that category 6 link and channel requirements are backward compatible to category 5e makes it very easy for customers to choose category 6 and supersede category 5e in their networks. Applications that worked over category 5e will work over category 6.
What does category 6 do for my current network vs. category 5e?
Because of its improved transmission performance and superior immunity from external noise, systems operating over category 6 cabling will have fewer errors vs. category 5e for current applications. This means fewer re-transmissions of lost or corrupted data packets under certain conditions, which translates into higher reliability for category 6 networks compared to category 5e networks.
When should I recommend or install category 6 vs. category 5e?
From a future proofing perspective, it is always better to install the best cabling available. This is because it is so difficult to replace cabling inside walls, in ducts under floors and other difficult places to access. The rationale is that cabling will last at least 10 years and will support at least four to five generations of equipment during that time. If future equipment running at much higher data rates requires better cabling, it will be very expensive to pull out category 5e cabling at a later time to install category 6 cabling. So why not do it for a premium of about 20 percent over category 5e on an installed basis?
What is the shortest link that the standard will allow?
There is no short length limit. The standard is intended to work for all lengths up to 100 meters. There is a guideline in ANSI/TIA/EIA-568-B.1 that says the consolidation point should be located at least 15 meters away from the telecommunications room to reduce the effect of connectors in close proximity. This recommendation is based upon worst-case performance calculations for short links with four mated connections in the channel.
What is a “tuned” system between cable and hardware? Is this really needed if product meets the standard?
The word “tuned” has been used by several manufacturers to describe products that deliver headroom to the category 6 standard. This is outside the scope of the category 6 standard. The component requirements of the standard have been carefully designed and analyzed to assure channel compliance and electrical/ mechanical interoperability.
What is impedance matching between cable and hardware? Is this really needed if product meets the standard?
The standard has no impedance matching requirements. These are addressed by having return loss requirements for cables, connectors, and patch cords.
Is there a use for category 6 in the residential market?
Yes, category 6 will be very effective in the residential market to support higher Internet access speeds while facilitating the more stringent Class B EMC requirements (see also the entire FCC Rules and Regulations, Title 47, Part 15). The better balance of category 6 will make it easier to meet the residential EMC requirements compared to category 5e cabling. Also, the growth of streaming media applications to the home will increase the need for higher data rates which are supported more easily and efficiently by category 6 cabling.
Why wouldn’t I skip category 6 and go straight to optical fiber?
You can certainly do that but will find that a fiber system is still very expensive. Ultimately, economics drive customer decisions, and today optical fiber together with optical transceivers is about twice as expensive as an equivalent system built using category 6 and associated copper electronics. Installation of copper cabling is more craft-friendly and can be accomplished with simple tools and techniques. Additionally, copper cabling supports the emerging Data Terminal Equipment (DTE) power standard under development by IEEE (802.3af).
What is meant by the term “Electrically Balanced”?
A simple open wire circuit consisting of two wires is considered to be a uniform, balanced transmission line. A uniform transmission line is one which has substantially identical electrical properties throughout its length, while a balanced transmission line is one whose two conductors are electrically alike and symmetrical with respect to ground and other nearby conductors.* “Electrically balanced” relates to the physical geometry and the dielectric properties of a twisted pair of conductors. If two insulated conductors are physically identical to one another in diameter, concentricity, dielectric material and are uniformly twisted with equal length of conductor, then the pair is electrically balanced with respect to its surroundings. The degree of electrical balance depends on the design and manufacturing process. Category 6 cable requires a greater degree of precision in the manufacturing process. Likewise, a category 6 connector requires a more balanced circuit design. For balanced transmission, an equal voltage of opposite polarity is applied on each conductor of a pair. The electromagnetic fields created by one conductor cancel out the electromagnetic fields created by its “balanced” companion conductor, leading to very little radiation from the balanced twisted pair transmission line. The same concept applies to external noise that is induced on each conductor of a twisted pair. A noise signal from an external source, such as radiation from a radio transmitter antenna generates an equal voltage of the same polarity, or “common mode voltage,” on each conductor of a pair. The difference in voltage between conductors of a pair from this radiated signal, the “differential voltage,” is effectively zero. Since the desired signal on the pair is the differential signal, the interference does not affect balanced transmission. The degree of electrical balance is determined by measuring the “differential voltage” and comparing it to the “common mode voltage” expressed in decibels (dB). This measurement is called Longitudinal Conversion Loss “LCL” in the Category 6 standard. * The ABC’s of the telephone Vol. 7
Category 6 Cable Questions
What is the difference between enhanced category 5e cable rated for 400 MHz and category 6 cable rated for 250 MHz?
Category 5e requirements are specified up to 100 MHz. Cables can be tested up to any frequency that is supported by the test equipment, but such measurements are meaningless without the context of applications and cabling standards. The category 6 standard sets minimum requirements up to 250 MHz for cables, connecting hardware, patch cords, channels and permanent links, and therefore guarantees reasonable performance that can be utilized by applications.
Why did all category 6 cable used to have a spline, and now is offered without one?
Some category 6 cable designs have a spline to increase the separation between pairs and also to maintain the pair geometry. This additional separation improves NEXT performance and allows category 6 compliance to be achieved. With advances in technology, manufacturers have found other ways of meeting category 6 requirements. The bottom line is the internal construction of the cable does not matter, so long as it meets all the transmission and physical requirements of category 6. The standard does not dictate any particular method of cable construction.
Is there a limitation on the size of bundles one can have with category 6? Can you have 200-300 and still pass category 6?
There is no limit imposed by the standards on the maximum number of category 6 cables in a bundle. This is a matter for the market and the industry to determine based on practical considerations. It should be pointed out that after six or eight cables, the performance in any cable will not change significantly since the cables will be too far away to add any additional external (or alien) NEXT.
Category 6 Patch Cord Questions
Will contractors be able to make their own patch cords?
Category 6 patch cords are precision products, just like the cables and the connectors. They are best manufactured and tested in a controlled environment to ensure consistent, reliable performance. This will ensure interoperability and backward compatibility. All this supports patch cords as a factory-assembled product rather than a field-assembled product.
Do you have to use the manufacturer’s patch cords to get category 6 performance?
The category 6 standard has specifications for patch cords and connectors that are intended to assure interoperable category 6 performance. If manufacturers can demonstrate that each component meets the requirements in the standard, minimum category 6 performance will be achieved. However, manufacturers may also design their products to perform better than the minimum category 6 requirements, and in these cases compatible patch cords and connectors may lead to performance above the minimum category 6 requirements.
Category 6 Testing Questions Why do field tester manufacturers offer many different link adapters if everyone meets the standard?
This was an interim solution while the standard was still being developed and the interoperability requirements were not yet established. It is likely that soon one or more adapters will work for testing of cabling from all vendors.
Would you get passing test results if you used a link adapter not recommended by a manufacturer?
You should expect to get passing results if both the link adapter interface and the mating jack that is part of the link are both compliant to category 6 requirements.
Category 6 Connecting Hardware Questions
Are the connectors for category 5e and category 6 different? Why are they more expensive?
Although category 6 and category 5e connectors may look alike, category 6 connectors have much better transmission performance. For example, at 100 MHz, NEXT of a category 5e connector is 43 decibels (dB), while NEXT of a category 6 connector is 54 dB. This means that a cat6 connector couples about 1/12 of the power that a cat5e connector couples from one pair to another pair. Conversely, one can say that a category 6 connector is 12 times less “noisy” compared to a category 5e connector. This vast improvement in performance was achieved with new technology, new processes, better materials and significant R&D resources, leading to higher costs for manufacturers.
What will happen if I mix and match different manufacturers’ hardware together?
If the components are category 6 compliant, then you will be assured of category 6 performance.
CAT5 Configuration
by John on Feb.21, 2010, under Networking, TIPS, Troubleshooting
Comments Off more...DOS Commands for TCP/IP and Networking
by John on Feb.20, 2010, under Networking, TIPS, Troubleshooting
There are dozens of networking tools available for Windows XP (For example, see this command-line reference.) Most of these are specialized and are mainly of interest to professionals who are maintaining a large network. Many, however, are relevant to the Internet and some of these can be helpful to the average PC user. The tools of interest to the discussion here are a few of of the TCP/IP utilities. (Go here for a complete list.) TCP/IP refers to the set of protocols that are used for Internet connections and on most networks. Discussing TCP/IP is beyond the scope of this page but more details are available on a separate page and in the references in the sidebar. Fortunately, it is not necessary to understand the gory details of TCP/IP in order to make practical use of the tools considered here.
All of the tools are run by opening a Command window and entering the appropriate command. Go to Start-Run and enter “cmd” to open a Command window.
Windows IP Configuration Tool (ipconfig)
The Windows IP Configuration tool (ipconfig) is the command-line equivalent of the accessory “Winipcfg” that was present in Windows 9X/Me. It is used to display the TCP/IP network configuration values. To open it, enter “ipconfig” in the command prompt. If you are connected directly to the Internet, you will obtain your IP address. (For a discussion of what an IP is, go here.) The figure below shows the result for a broadband connection where the IP is assigned automatically. Here the IP is your computer’s temporary address on the Internet.
If you are on a local area network using a router, the information is different. You do not obtain the IP corresponding to the network’s address on the Internet. (To obtain the IP that the Internet sees, go to a source such as DSL Reports Whois.) The IP given is the local address on the network. This information can be helpful in diagnosing network problems. Also listed is the “gateway” or router address on the local network. The figure below illustrates the result.
Switches for IPConfig
There are also a variety of switches for ipconfig that add functions. These are invoked by entering “ipconfig /{switch}“. To obtain a list of switches, enter “ipconfig /?” or “ipconfig -?“. These are shown in the figure below. The switches of most interest to everyday use are “release” and “renew“. Note that IP addresses are typically assigned or “leased” for a period of time, often a day or more. It sometimes happens that IP addresses are no longer valid or are in conflict. Problems can often be solved by first releasing the IP address and then renewing it. Sometimes cable or DSL modems that seem to be disabled can be restored this way. If you travel and use broadband connections elsewhere, you will often find this procedure of releasing and renewing the IP address to be necessary.
For a detailed output of network parameters, you can use the command "ipconfig /all". Unless you are experienced with networks, however, this may be more than you want to know.
The switches “flushdns” and “displaydns” are are also sometimes useful in everyday use and they are discussed on another page at a sister site.
Ping
Ping is an old Unix tool that has been around for a long time but many PC users are unfamiliar with the Windows version. Ping sends out a packet to a designated internet host or network computer and measures its response time. The target computer will return (hopefully) a signal. It is a way of determining the quality of your connection to another site. You will also receive an IP address that corresponds to the user-friendly type of URL (see this page for further discussion of IPs and URLs). To use ping, open a command window (or DOS in Windows 9X/Me) and type: ping <hostname>. For example, to ping Dell enter: ping dell.com Please note the use of a hostname, not a complete URL. The prefix “http://” is never used. Many sites also do not require “www” . By convention, 32 byte packets will be transmitted four times. You will receive a screen output that looks like:
The screen tells me that the IP for dell.com is 143.166.83.230 (For the moment, at least. This can change.) It also tells me that the average round trip time for a packet was 69 milliseconds, which means I have a good connection to dell.com. Long reply times of several hundred milliseconds are indicative of a slow connection. Note that some major sites such as microsoft.com do not like being pinged and block pings. In that case you will get a “Request timed out” message.
In addition to being used on the Internet, Ping is often used to test connections on local networks. More details can be found in this Microsoft article.
Tracert
Tracert (traceroute) is another old tool borrowed from Unix. The actual path between two computers on the Internet is not a straight line but consists of numerous segments or “hops” from one intermediate computer to another. Tracert shows each step of the path taken. It can be interesting to see just how convoluted it is. The times for each hop and the IP addresses for each intermediate computer are displayed. Tracert shows up to 30 hops. It is convenient for finding if there is one particular segment that is causing a slow or bad connection. A typical command might be “tracert dell.com”.
Pathping
This command combines functions of Ping and Tracert. Pathping will first list the number of hops required to reach the address you are testing and then send multiple pings to each router between you and the destination. After that, it computes results based on the packets returned from each router. Because pathping displays the degree of packet loss at any given router or link, you can determine which routers or subnets might be having network problems. Note that the whole process may consume 5-10 minutes because many pings are being sent. There are switches to modify the process and these can be seen by entering “pathping /?” in the command prompt.
Netstat
Netstat displays the active TCP connections and ports on which the computer is listening, Ethernet statistics, the IP routing table, statistics for the IP, ICMP, TCP, and UDP protocols. It comes with a number of switches for displaying a variety of properties of the network and TCP connections. (One tricky point: the switches must be prefixed with a minus, not a slash.) More detail is at this page. One possible use for Netstat is to determine if spyware or Trojans have established connections that you do not know about. The command “netstat -a” will display all your connections. The command “netstat -b” will show the executable files involved in creating a connection. A figure showing all the switches and syntax is given below.
Nslookup
This command helps diagnose the Domain Name System (DNS) infrastructure and comes with a number of sub-commands. These are mainly for systems administrators. The primary interest for average PC users is its use to find the computer name corresponding to a numeric IP. For example, if you want to know who is “216.109.112.135″ , enter “nslookup 216.109.112.135″ and you will find that it is (or was anyway) a Yahoo computer. My firewall keeps a log of the IPs involved in the attempts to probe my computer and I sometimes look a few up to see who they are. (There are also Whois search sites available on the Web as mentioned in the Ipconfig section.)
Netsh
The network services shell is a large suite of many tools. I discuss it in some depth on another page